SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Timer
Description
Engineer
Engineer
The timer for the Engineer access starts as soon as the user enables the Engineer
Access
Access. (0–999 minutes; 0 indicates no time limitation for system access)
ENGINEER
ACCESS
Engineer auto
Duration of inactivity after which the engineer will be automatically logged out. (0–300
log out
minutes)
ENG AUTO
LOG OUT
Keypad
Keypad Timeout
The number of seconds that an RKD will wait for key entry before it leaves the current
menu. (10–300 seconds)
KEYPAD
TIMEOUT
Keypad
The duration a keypad will wait in idle before switching language to default. (0–9999
Language
seconds; 0 = never)
KEYPAD
LANGUAGE
Fire
Fire Pre-alarm
Number of seconds to wait before reporting fire alarm for zones with 'Fire pre-alarm'
attribute set. See Editing a zone on page 272. (1–999 seconds)
FIRE PRE-
ALARM
Fire recognition
Extra time to wait before reporting file alarm for zones with 'Fire pre-alarm' and 'Fire
Recognition' attributes set. See Editing a zone on page 272. (1–999 seconds)
FIRE
RECOGNITION
PIN
PIN Valid
Period for which pin is valid. (1–330 days)
PIN VALID
PIN Changes
Number of changes within a valid period. (1–50)
Limit
PIN CHANGES
LIMIT
PIN Warning
Time before PIN expiry after which a warning will be displayed. (1–14 days)
PIN WARN
General Settings
RF Output Time
The time that the RF output will remain active on the system. (0–999 seconds)
RF OUTPUT
© Vanderbilt 2018
120
Engineer programming via the keypad
A6V10276959-d
12.09.2018
Default
0min.
0min.
30sec.
10sec.
30sec.
120sec.
30 days
5
5 days
0sec.