SPC4xxx/5xxx/6xxx – Installation & Configuration Manual
Relay Outputs
Electronic Outputs
Firmware
Door capacity
Number of card reader
Radio module
Verification
Video
Audio
Field bus 1)
Number of field devices 2)
Connectable field devices
Interfaces
Tamper contact
Power supply
Mains voltage
Mains fuse
© Vanderbilt 2018
SPC6320/6330 — 1 strobe (30V DC/1A resistive switching current)
l
SPC6350 — 4 (single-pole changeover, 30V DC/ maximum 1A resistive
l
switching current)
SP6320/6330 — 5 outputs:
l
– 2 internal/external bells
– 3 programmable. Maximum 400mA resistive switching current per
output, supplied by auxiliary output.
SPC6350 — 8 outputs. Maximum 400mA resistive switching current per
l
output
– 5 standard power outputs
– 3 supervised outputs
V3.x
Max. 64 entry doors or 32 entry/exit doors
Max. 64
Optional (SPCW110)
32 verification zones with max. 4 IP-cameras and 32 audio devices.
Up to 16 pre/16 post event images (by JPEG resolution 320 x 240, max. 1
frame/sec.)
Up to 60sec. pre/60sec. post audio recording
X-BUS on RS-485 (307kb/s)
Max. 128 (32 keypads, 32 door-expanders, 64 input/output expanders)
Keypads: SPCK42x, SPCK62x
l
Door expanders: SPCA210, SPCP43x
l
Expanders with I/O: SPCE65x, SPCE45x, SPCP33x, SPCP35x,
l
SPCE110, SPCE120, SPCV32x
2 X-BUS (2 spurs or 1 loop)
l
2 RS232
l
1 USB (PC connection)
l
SPC63xx: Additionally 1 Ethernet (RJ45)
l
SPC6330: Front spring tamper, 2 auxiliary tamper contact inputs
l
SPC6350: Front/back tamper switch
l
Type A (per EN50131-1)
230V AC, +10%/-15%, 50Hz
SPC6330: 250mA T (replaceable part on mains terminal block)
l
SPC6350: 800mA T (replaceable part on mains terminal block)
l
38
Technical Data
A6V10276959-d
12.09.2018