INSPECTION PROCEDURE: P0653
1
Inspect the power supply of common rail pressure sensor 2
E1
Do the measurements meet the standard value?
Go to step 2.
ENGINE (J05E)/TROUBLESHOOTING
1.
Set the starter key to the "LOCK" position.
VC1
2.
Disconnect the common rail pressure sensor 2 connector.
3.
Set the starter key to the "ON" position.
4.
Use the electrical tester to measure the voltage between the termi-
nals of the common rail pressure sensor 2 vehicle side connector.
SHTS021270300621
Starter key: ON
YES
Measurement
Tester
conditions
connections
Common rail pres-
sure sensor 2
vehicle side con-
nector
VC1 – E1
Repair or replace the harness.
Perform "After-inspection work" of INFOR-
MATION section.
2–679
Standard values
4.5 – 5.5 V
NO