Dtc: P041C And P041D; P041C: Egr Gas Temperature Sensor - Out Of Range (Out Of Range Low) - Hino Motors HINO 155 series Workshop Manual

Table of Contents

Advertisement

2–518

DTC: P041C and P041D

P041C: EGR gas temperature sensor - out of range (Out of range low)

INFORMATION
temperature sensor
Boost pressure sensor
1.
Technical description
• The installed EGR cooler outlet temperature sensor consistently measures temperature at the outlet of the EGR
cooler.
<Description of malfunction>
• EGR cooler outlet temperature cannot be correctly recognized.
2.
DTC set condition
(1)
DTC detection condition
• Starter key is "ON".
• The condition that fuel injection quantity is 40 mm
• The battery voltage is in the range of 10 to 16 V.
• The engine is stopped, or the engine speed remains at 500 r/min or more for 5 seconds or more.
(2)
Judgement criteria
• Output of the sensor remains at 0.27 V or less (740 C {1364 F} or higher) for 3 seconds or longer.
3.
Reset condition
• After restoration to normal condition
4.
Indication, warning or system control regulation when the DTC is set.
• MIL: ON
• SVS light: OFF
ENGINE (J05E)/TROUBLESHOOTING
EBK
(E1)
EBJ
(PCR1)
EBH
(VC1)
Common rail
EBN
(E2)
pressure sensor
EBM
(PCR2)
EBL
(VC2)
X7U
(THG)
EGR cooler outlet
Z2N
(E2)
J0M
(VC)
J0L
(PIM)
Z6R
(E)
Engine ECU
$XV
(PC1S)
15mA
Z70
(E1)
2mA
XZG
(PCR1)
15mA
X85
(VC)
15mA
Z72
(E2)
2mA
XZH
(PCR2)
15mA
XG2
(VC2)
$XW (PC2S)
10mA
X4A
(THG)
10mA
15mA
5mA
X0G (PIM)
15mA
ZJP (E4)
3
/sc.cyl or less remains for 10 seconds or more.
EN01H02127030602016079