Check For +B/Gnd Short-Circuit In Can L-Line - Hino Motors HINO 155 series Workshop Manual

Table of Contents

Advertisement

2–50
3

Check for +B/GND short-circuit in CAN L-line

+B2
GND4
GND1
LEP
LEW
LET
+24V
K9G
+B3
GND5
GND2
ISOK
LEQ
LEX
LEU
K9E
+B4
+B1
GND3
LER
LEN
LEV
CAH1
LF5
CAL1
LF6
TE1B
LF2
TE1A
CAH0
LF1
LEY
TE2B
CAL0
LF4
LEZ
TE2A
LF3
ISGW
LES
Do the measurements meet the standard value?
Go to step 4.
ENGINE (J05E)/TROUBLESHOOTING
1.
CAN-
TC
DSW
KS4
KS2
KPZ
CAN+
SGND
CGFR
+
KS3
K9H
L30
KE4
SHTS021270300029
YES
Use the electrical tester to check the continuity between the follow-
ing terminals.
(1) Between the CAL0 terminal in the DCU (53P) vehicle side
connector and the 16th terminal in the DLC(16P).
(2) Between the CAL0 terminal in the DCU (53P) vehicle side
connector and the 4th terminal in the DLC(16P).
Measurement
conditions
connections
DCU vehicle-side
connector –
Diagnostic con-
Starter key: LOCK
nector
CAL0 – 16th
CAL0 – 4th
Refer to "DISCONNECTION INSPECTION
FOR ENGINE CAN_H COMMUNICATION L
LINE (250 k)" and check the CAN bus line.
Tester
Standard values
No Continuity
NO

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hino 195h seriesHino 155h seriesHino 195 series

Table of Contents