P007D: Intake Air Temperature Sensor (Intercooler Outlet) Out Of Range - Hino Motors HINO 155 series Workshop Manual

Table of Contents

Advertisement

2–162
P007D: Intake air temperature sensor (intercooler outlet) - out of range (Out of range high)
INFORMATION
Common rail
pressure sensor
Exhaust gas
temperature sensor
Boost pressure sensor
Intercooler outlet
temperature sensor
1.
Technical description
• The intake air temperature sensor (intercooler outlet) installed to the downstream of the boost pressure sensor con-
sistently measures temperature at the outlet of the intercooler.
<Description of malfunction>
• The intake air temperature at the intercooler outlet cannot be correctly recognized.
2.
DTC set condition
(1)
DTC detection condition
• Starter key "ON".
• Battery voltage is in the range of 10 V to 16 V.
• The engine is stopped, or the engine speed remains at 500 r/min or more for 5 seconds or more.
• Intake air temperature is -20 C {-4 F} or more.
(2)
Judgement criteria
• Output of the intake air temperature sensor (intercooler outlet) remains at 4.87 V (-35 C {-31 F}) or higher for
3 seconds or longer.
3.
Reset condition
• After restoration to normal condition
4.
Indication, warning or system control regulation when the DTC is set.
• MIL: ON
• SVS light: OFF
ENGINE (J05E)/TROUBLESHOOTING
15mA
EBK
E1
2mA
EBJ
PCR1
15mA
EBH
VC1
15mA
EBN
E2
2mA
EBM
PCR2
15mA
EBL
VC2
10mA
X7U
(THG)
10mA
Z2N
(E2)
15mA
J0M
(VC)
5mA
J0L
(PIM)
15mA
Z6R
(E)
10mA
E7Q
(E2)
E7P
10mA
(THG)
Engine ECU
$XV
(PC1S)
Z70
(E1)
XZG
(PCR1)
X85
(VC)
Z72
(E2)
XZH
(PCR2)
XG2
(VC2)
$XW
(PC2S)
X4A
(THG)
X0G (PIM)
ZJP
(E4)
XSW
(THAO)
SHTS021270300150