2–668
INSPECTION PROCEDURE: P064C
1
Inspect the fuse (GCU (M)), fusible link (GLOW)
Was any failure found?
Replace or correctly connect the fuse and
fusible link.
Perform "After-inspection work" of INFOR-
MATION section.
2
Inspect the ground circuit of the glow control unit
GND
Do the measurements meet the standard value?
Go to step 3.
ENGINE (J05E)/TROUBLESHOOTING
1.
Check if the fuse (GCU (M)) and fusible link (GLOW) are blown
and if they are properly installed.
YES
1.
Set the starter key to the "LOCK" position.
2.
Disconnect the GCU connector.
3.
Use the electrical tester to measure the resistance between the
glow control unit GND terminal and ground.
Starter key: LOCK
SHTS021270300609
YES
Go to step 2.
Measurement
Tester
conditions
connections
GCU vehicle side
connector
GND – Ground
Inspect the GCU ground circuit.
Perform "After-inspection work" of INFOR-
MATION section.
NO
Standard values
Less than 1
NO