2–634
3
Inspect for short-circuit of the wire harness of the starter key "Start" signal
A
V12
Do the measurements meet the standard value?
Go to step 4.
ENGINE (J05E)/TROUBLESHOOTING
1.
Set the starter key to the "LOCK" position.
2.
Disconnect the neutral start switch.
3.
Use the electrical tester to measure the resistance between the
engine ECU (signal check harness) and ground.
SHTS021270300578
Starter key: LOCK
YES
Measurement
Tester
conditions
connections
Engine ECU (sig-
nal check har-
ness) – ATM
starter relay con-
nector
ST (V12) – Ground
Repair or replace the harness.
(Engine ECU – Neutral start switch)
Perform "After-inspection work" of INFOR-
MATION section.
Standard values
NO