2–758
3
Inspect the differential pressure sensor unit
VC
PEX
Do the measurements meet the standard value?
Go to step 4.
ENGINE (J05E)/TROUBLESHOOTING
1.
Set the starter key to the "LOCK" position.
2.
Disconnect the DPR differential pressure sensor connector.
E2
3.
Use the electrical tester to measure the resistance between the
terminals of the differential pressure sensor.
E2
SHTS021270300686
YES
Measurement
conditions
connections
Differential pres-
sure sensor
Starter key: LOCK
VC – E2
PEX – E2
Replace the differential pressure sensor.
Perform "After-inspection work" of INFOR-
MATION section.
Tester
Standard values
2 – 15 k
NO