P081A: Starter Disable Circuit Low; Dtc: P081A - Hino Motors HINO 155 series Workshop Manual

Table of Contents

Advertisement

2–720

DTC: P081A

P081A: Starter Disable Circuit Low

INFORMATION
+B
+B
ST
Ignition switch Neutral start switch
1.
Technical description
• The starter cut relay prevents further rotations of the starter when the starter key is turned after start of the engine.
<Description of malfunction>
• Harness GND short-circuit or disconnection and relay unit failure are detected.
2.
DTC set condition
(1)
DTC detection condition
• Engine speed of 650 r/min or more. (Request starter cut relay operation)
• Starter key "ON".
• Battery voltage is in the range of 10 V to 16 V.
The conditions described above remain for 5 seconds or longer.
(2)
Judgement criteria
• Output of the starter cut relay remains at 10 V or less for 3 seconds or longer.
3.
Reset condition
• Just after restoration to normal condition
4.
Indication, warning or system control regulation when the DTC is set.
• MIL: OFF
• SVS light: OFF
5.
Symptoms on the vehicle when the DTC is set
<Symptoms on the vehicle due to backup control (fail safe function)>
• –
<Symptoms on the vehicle due to malfunction>
• Starter operates even when the engine is running.
6.
Pre-inspection work
• Check that the battery voltage is in the normal range.
7.
After-inspection work
• Clear all past DTCs.
• Check that no DTC is stored after test drive.
ENGINE (J05E)/TROUBLESHOOTING
ST1
STA
Engine
ECU
+B
Starter relay
Fuse
+ST
STCR
Starter cut relay
EN01H02127030602016118
To starter
SHTS021270300658

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Hino Motors HINO 155 series

This manual is also suitable for:

Hino 195h seriesHino 155h seriesHino 195 series

Table of Contents