INSPECTION PROCEDURE: P007C and P007D

1

Inspect the intercooler outlet temperature sensor connector

Was any failure found?
Connect securely, repair if needed.
Perform "After-inspection work" of INFOR-
MATION section.
2
Inspect the intercooler outlet temperature sensor
Was any failure found?
Clean the sensing unit and install it properly.
If damaged, replace the sensor.
Perform "After-inspection work" of INFOR-
MATION section.
ENGINE (J05E)/TROUBLESHOOTING
1.
Check the connection of the intercooler outlet temperature sensor
connector (looseness and poor contact).
YES
1.
Check the installation of the intercooler outlet temperature sensor.
2.
Make sure there is no dirt, damage or clogging in the sensing unit
of the intercooler outlet temperature sensor.
YES
NO
Go to step 2.
NO
Go to step 3.