6.
Pre-inspection work
• Check that the battery voltage is in the normal range.
7.
After-inspection work
• Clear all past DTCs.
• Check that no DTC is stored after test drive.
8.
Estimated failure factors
• Harness disconnection or short-circuit between GCU and glow plug #2
• Glow plug #2 unit is faulty.
ENGINE (J05E)/TROUBLESHOOTING
2–687