Hino Motors HINO 155 series Workshop Manual page 294

Table of Contents

Advertisement

2–258
9
Inspect the engine coolant temperature sensor 2 unit
E22
Do the measurements meet the standard value?
Go to step 10.
10
Inspect the engine coolant temperature sensor 2 power supply
THW2
Do the measurements meet the standard value?
Go to step 13.
ENGINE (J05E)/TROUBLESHOOTING
1.
THW2
2.
3.
SHTS021270300236
YES
1.
E22
2.
SHTS021270300237
YES
Set the starter key to the "LOCK" position.
Disconnect the engine coolant temperature sensor 2 connector.
Use the electrical tester to measure the resistance between the
terminals of the engine coolant temperature sensor 2.
Measurement
conditions
connections
Engine coolant
temperature sen-
Starter key: LOCK
sor 2
E22 – THW2
Replace the engine coolant temperature sen-
sor 2.
Perform "After-inspection work" of INFOR-
MATION section.
Set the starter key to the "ON" position.
Use the electrical tester to measure the voltage between the termi-
nals of the engine coolant temperature sensor 2 vehicle side con-
nector.
Measurement
conditions
connections
Engine coolant
temperature sen-
Starter key: ON
sor 2 vehicle side
connector
THW2 – E22
Go to step 11.
Tester
Standard values
20 C {68 F}:
2.59 – 2.32 k
80 C {176 F}:
0.326 – 0.310 k
NO
Tester
Standard values
4.5 – 5.5 V
NO