INSPECTION PROCEDURE: P0381
1
Inspect the combination meter connector
Was any failure found?
Connect securely, repair if needed.
Perform "After-inspection work" of INFOR-
MATION section.
2
Check the combination meter operation
Was any failure found?
Inspect the combination meter.
Perform "After-inspection work" of INFOR-
MATION section.
ENGINE (J05E)/TROUBLESHOOTING
1.
Check the connection of the combination meter connector (loose-
ness and poor contact).
YES
1.
Set the starter key to the "ON" position.
2.
Check the operation of the combination meter (various instruments
and displays).
YES
NO
Go to step 2.
NO
Go to step 3.
2–463