2–610

INSPECTION PROCEDURE: P0562 and P0563

1

Inspect the fuse or fusible link

Was any failure found?
Connect the fusible link properly or replace.
Perform "After-inspection work" of INFOR-
MATION section.
2

Inspect the connection of the battery cable

Was any failure found?
Connect properly. If necessary, repair the
cable.
Perform "After-inspection work" of INFOR-
MATION section.
3

Inspect the alternator

Do the measurements meet the standard value?
Go to step 4.
ENGINE (J05E)/TROUBLESHOOTING
1.
Check for fusing or improper fit.
YES
1.
Check if the battery cable is properly installed (tightly fastened).
• Each battery terminal
• Alternator terminal
YES
1.
Start the engine.
2.
Use the electrical tester to measure the voltage between the alter-
nator B terminal and ground.
Measurement
Engine idling
YES
Go to step 2.
Go to step 3.
Tester
conditions
connections
Alternator B –
Ground
Repair or replace the alternator.
Perform "After-inspection work" of INFOR-
MATION section.
NO
NO
Standard values
13.5 V or more
NO