15.2 Error Code Details

15.2.1 Error Code Details

Code
Cause
E000
The temperature of the fixing assembly is abnormally high.
0001 While startup control is under way,
the reading of the main thermistor is
less than 30 deg C continuously for
200 msec or more 1 sec after the start
of power supply.
While startup control is under way,
the reading of the main thermistor is
less than 70 deg C continuously for
200 msec or more 2 sec after the start
of power supply.
While startup control is under way,
the reading of the main thermistor is
less than 120 deg C continuously for
200 msec 6 sec after the start of
power supply.
The startup control does not end 30
sec after the start of power supply.
E001
The temperature of the fixing assembly is abnormally high.
0000 The reading of the main thermistor is
250 deg C or more continuously for
200 msec.
0001 The hardware circuit detects
overheating of the main or sub
thermistor for 200 msec.
T-15-2
Remedy
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Replace the main thermistor. Replace
the DC controller PCB.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Replace the main thermistor. Replace
the DC controller PCB.
Reset the condition in service mode:
COPIER>FUNCTION>CLEAR>ERR.
Replace the DC controller PCB.