Chapter 3 Error Code; Error Code Details - Canon iR2030 Portable Manual

Hide thumbs Also See for iR2030:
Table of Contents

Advertisement

Chapter 3 Error Code

3.1 Error Code Details

3.1.1 Error Code Details
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Display
Detail Code
Code
E000
0000
E001
0000
0001
E002
0000
E003
0000
0001
E007
0000
E010
0000
E019
0000
0001
E052
0000
E100
0000
Main Cause/Symptom
Startup error
The temperature detected by the main or sub thermistor does
not rise to the specified value during startup control.
Abnormally high temperature (detected by main thermistor)
The main thermistor detected an abnormally high temperature
(240 deg C) during temperature control.
Abnormally high temperature (detected by sub thermistor)
The sub thermistor detected an abnormally high temperature
(295 deg C) during temperature control.
Low temperature during temperature control.
The target temperature is not reached during temperature
control.
Abnormally low temperature (detected by main thermistor)
After the temperature detected by the main thermistor has
reached the specified value, it does not reach the specified value
during initial rotation.
Abnormally low temperature (detected by sub thermistor)
After the temperature detected by the sub thermistor has
reached the specified value, it does not reach the specified value
during initial rotation.
Fixing film sensor failure
The fixing film sensor is faulty.
Main motor failure
The main motor is faulty.
Waste toner full detection
The waste toner full state was detected.
Waster toner full detection sensor is faulty.
The waste toner full state was detected continuously for five or
more seconds while the main motor was turning.
Erroneous connection to duplex unit
Disconnection of the duplex unit was detected after power-on,
detection of normal connection to the duplex unit, and start of
communication.
BD detection PCB failure
The BD detection PCB is faulty.
T-3-1
- Check the fixing film connector.
- Replace the fixing film unit.
- Replace the DC controller PCB.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
- Check the connector of the fixing film sensor.
- Replace the fixing film sensor.
- Replace the DC controller PCB.
- Check the connector of the main motor.
- Replace the main motor.
- Replace the DC controller PCB.
Replace the drum unit.
- Check the connector of the waster toner full sensor.
- Replace the waste toner full sensor.
- Replace the DC controller PCB.
- Check the connectors of the duplex unit and DC controller PCB.
- Replace the duplex controller PCB.
- Replace the DC controller PCB.
- Check the connector of the BD detection PCB.
- Replace the laser scanner unit.
- Replace the DC controller PCB.
Countermeasure