2.8.2.2 Removing the Original Pickup roller/Original Separation roller
1) Remove the separation roller unit. (See
2.8.2.1)
2) Free the 2 hooks [1], and detach the
original pickup roller [2].
3) Free the 2 hooks [3], and detach the
original separation roller [4].
2.8.2.3 Removing the Original Sensor/Registration Sensor
1) Remove the ADF motor unit. (See
2.8.1.3)
2) Free the 2 hooks [1], and detach the
original sensor [2].
3) Free the 2 hooks [3], and detach the reg-
istration sensor [4].
5-56
COPYRIGHT © 2001 CANON INC.
[1]
2000 2000 2000 2000
CANON SmartBase PC1200s/iR1200s REV. 0 DEC. 2001
[1]
[2]
[4]
[3]
F05-208-16
[1]
[2]
[4]
F05-308-17
[3]