9 Purchasable Options

The system supports the following configuration options:
Table 18: Standard Software Option Keys
Option
70 kV Scan Mode
High Definition
Cardiac Scan Modes
ECG Gating
Temporal Enhance
SmartPrep with Dynamic Transition
Overlapped Recon
Organ Dose Modulation
Digital Tilt
0.28 Sec Rotation
256 Slice
3D Dose Modulation
Dynamic Perfusion
CARDIQ Xpress 2.0 Reveal
AutoBone Xpress
Advanced Vessel Analysis Xpress — AVA Express
CT Colon (CTC) Pro 3D_EC — CT Colon Pro 3D
CardEP
Volume Viewer 5.0 — Volume Viewer
CT Perfusion 4D Multi-Organ — Perfusion 4D
CT Perfusion 4D Neuro — Perfusion 4D Neuro
Chapter 8 Equipment
Description
Enables 70 kV scan mode.
Enables High Resolution scanning (focal spot deflection). Only available
with GE Tube.
Enables Cardiac scan acquisition modes, External ECG gating and guides
the user in selecting the appropriate cardiac imaging mode based on pa‐
tient profile.
Provides retrospective review of the gating information and capability to
edit the triggering information on the ECG waveform.
Enables internal ECG trigger device. Provides capability to display and
view the ECG waveform on the operator console.
Enables Temporal Enhance prescription used with Snapshot Freeze mo‐
tion correction.
Reconstruction mode to create images to support SnapShot Freeze car‐
diac image post processing.
Enables real-time monitoring of IV contrast and a user-selectable mode to
dynamically transition to the diagnostic scan phase when a user entered
Enhancement Threshold is reached in the Transition ROI.
Overlapped image reconstruction for Axial scan type generates 512 im‐
ages from a 160mm acquisition.
mA profile as a function of tube angle to reduce organ specific dose.
Protocols that allows prospective tilted MPR.
Enables 0.28 second scanning.
Enables up to 256 slice detector coverage, increasing coverage to 160 mm
from default of 80 mm.
Rotational and Z-axis dose modulation.
Enables protocols that use multiple groups to accomplish variable sam‐
pling.
Provides the user with multiple tools to post process images from cardiac
data sets.
Facilitates removal of bone and CT table from CT Angiography (CTA)
studies of the abdomen and lower extremities.
Provides enhanced analysis of vascular features, which include stenosis
analysis, pre/post stent planning procedures and directional vessel tortuos‐
ity visualization.
Provides comprehensive software package for evaluation of quick, accu‐
rate, noninvasive colon exams.
Post processing image analysis software for the application of cardiovas‐
cular and electrophysiology imaging.
Provides protocols for reformat, 3D rendering and volume rendering.
Multi-organ package includes protocols for neuro stroke and tumor perfu‐
sion imaging and body tumor including liver perfusion imaging.
Package includes protocols for neuro stroke and brain tumor perfusion.
Revolution CT User Manual
Direction 5480385-1EN, Revision 1
189