Adjust Pediatric And Small Patient Scan Parameters; Adjust The Parameters By Size, Age, Weight, Height, And Indications - GE Revolution CT User Manual

Tomography scanner
Table of Contents

Advertisement

, in the upper left corner.
Patient Information screen displays the new Exam Number .
The
The maximum
Patient Information area, type data into the appropriate fields.
2. From the
Press <Tab> to advance to the next field. Alternatively, use the mouse to navigate to
each field.
Patient ID is a required field. If the patient does not have an identification number, type ?
or the word trauma.
3. Click [Pediatric].
Pediatric Protocol Selection screen, click an anatomical area.
4. From the
With the patient's weight entered, the system automatically selects the appropriate
pediatric color code area for the anatomical area selected.
Use the arrows to scroll through the list.
Click a protocol from the list to download the scan parameter values.
Pediatric Protocol Category screen, select the weight/length category based on
5. From the
the size of your patient or verify the correct Color category has been selected if you entered
a weight.
The protocols in the selected color code are then displayed accordingly.
The default weight/color selector displays the patient weight entered on the
Information screen, or the last weight/color selection (if no patient information was
entered).
If you enter a patient weight on the
that is not consistent with the entered information, a red alert displays next to the
protocol name. You must acknowledge that you have chosen a protocol that does NOT
match the patient size.
Alert message: Selected color is not suitable for the entered patient weight of 29 Kg (65
lbs).
6. Proceed with the Acquire a Scout scan procedure.

3.5 Adjust pediatric and small patient scan parameters

Use the following guidelines for adjusting individual exposure parameters by patient.

3.5.1 Adjust the parameters by size, age, weight, height, and indications

Use pediatric protocols based on the age, weight, height, and indications to avoid over
exposure.
Chapter 5 Pediatrics and Small Patients
Exam Number is 49,999, which is reset by your Field Engineer.
Patient Information screen and select a color/weight
Revolution CT User Manual
Direction 5480385-1EN, Revision 1
Patient
129

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Revolution CT and is the answer not in the manual?

Questions and answers

Greg Lesco
February 27, 2025

need a part number for the Integrated Cardiac Patient Monitor, patient grounding strap + cable

Yaya
March 14, 2025

How do I clear Ge Revolution collision sensor

1 comments:
Mr. Anderson
March 14, 2025

To clear the collision sensor on a GE Revolution CT, remove any obstructions detected by the sensors located beneath the front and back of the table. Once the area is clear, you can continue positioning the table.