Ricoh C211 Service Manual page 656

Table of Contents

Advertisement

9. Table of Defective Electrical Components: SS830
Component
Condition
Phenomenon
2nd Original Sensor
ON condition
When the main switch is turned on, the Jam
(Feeler is
indicators "A" + ~ blink and reset is impos-
actuated)
sible.
OFF condition
The original is fed when the Start key is
(Feeler is not
pressed, but the jam indicators "A" + ~
actuated)
blink
and
the
original
leading
edge
damages
because
the original transport
motor does not turn on.
Original Registra-
ON condition
After the master paper is ejected, the Jam
tion Sensor
(Feeler is
indicators "A" + ~ blink.
actuated)
OFF condition
The original is fed until the leading edge of
(Feeler is not
the original goes 5 cm past the exposure
actuated)
glass, then jam indicators "A" + ~ blink.
Master Eject Switch
ON condition
After the master is ejected and one sheet of
(Feeler is
paper (trial print) is delivered, the jam un-
actuated)
dicators "F" + 3$ blink and reset is impos-
sible.
OFF condition
When the master is being ejected, the jam
(Feeler is not
indicators "F" + ~
blink.
actuated)
Pressure Plate Posi-
ON condition
The pressure plate does not go up.
After
tion Switch
(Feeler is
one sheet of paper (trial print) is delivered,
actuated)
the jam indicators "F" + & blink.
OFF condition
When the main switch is turned on, the
(Feeler is not
pressure plate keeps moving up and down.
actuated)
After the master eject process is completed,
the jam indicators "F" + & blink.
Full Master Detect-
ON condition
When the master eject box is full, the full
ing Switch
(Feeler is
master indicators "F" + & do not blink.
actuated)
OFF condition
After master ejection is complete, the indi-
(Feeler is not
caters "F" + &
blink.
actuated)
6-34

Advertisement

Table of Contents
loading

This manual is also suitable for:

C216C212C224

Table of Contents