2.
Adjusting The Distance Between The Press Roller and The Drum
I
/
0.6 — 1.Omm
Purpose :
To ensure that the press roller does not contact the clamper section of the
drum.
Method :
1.
2.
3.
4.
Remove the rear cover of the machine (6 screws).
Using
a (lOmm)
open
end
wrench,
turn
the
drum
rotation
shaft
counterclockwise and position the bearing of the pressure release arm [A] on
top of the pressure cam [B].
While holding this condition, make sure that the distance between the
press roller [C] and the tip of the clamper [D] is 0.6 to 1.0 mm.
If incorrect, loosen the hexagon nut [E] and adjust the clearance by turn-
ing the screw [F].
5-53
Rev. 8/89