2. Adjusting The Original Pressure Solenoid
[E],
Purpose :
To ensure that the originals are separated properly.
Method :
1.
2.
3.
4.
5.
6.
7.
Remove the screw securing the stopper [A].
Remove the platen plate [B].
Remove the original guide [C].
Remove the ADF unit cover [D]
Remove hook springs [E].
(5 screws).
Remove the separation guide plate [F].
Adjust the original pressure solenoid [G] and position it so that the space
between the E-ring and the rubber cushion is 6.0 to 6.5 mm when the
solenoid is turned off.