Ricoh C211 Service Manual page 195

Table of Contents

Advertisement

10.6 VACUUM UNIT REPLACEMENT
/l
I
[D]
1. Remove both front and rear covers of the machine.
2. Remove the antistatic brush bracket [A] (4 screws),
3, Remove the harness clamp [B] (1 screw),
4. Disconnect the sensor connectors [C].
5, Disconnect the vacuum motor connector [D],
6, Remove the vacuum unit [E] (2 screws).
5-83

Advertisement

Table of Contents
loading

This manual is also suitable for:

C216C212C224