6.3 FULL MASTER SWITCH ADJUSTMENT
[c]
[D]
[B]
ii
0.1-0.5
mm
Purpose: To ensure that the full master detecting switch turns on when the
10
2.
30
4.
5.
master eject box is filled to capacity with ejected masters.
Open the master eject unit and remove the front cover of the master eject
unit (3 screws),
Turn the gear [A] and position the pressure plate at its lowest position. Then,
turn the gear further so that the arm [B] turns on the full master detecting
switch [C].
Confirm that the distance between the full master detecting switch and the
switch actuator [D] is 0.1 to 0.5 mm when the full master detecting switch
turns on.
If it is out of adjustment, loosen the screws [E] and adjust the position of the
full master detecting switch.
Tighten the mounting screws [E].
5-33