9.5 MASTER FEED CLAMPER CAM ADJUSTMENT
——.
ON= 29*0.5
mm
OFF= less
than 25
mm
Purpose: To ensure that the master feed clamper is opened during the master
1.
2.
3.
4.
5.
6,
feed process and is closed during other processes.
Remove the drum unit from the machine and open the master eject unit.
Remove the rear cover of the machine
Access 1/0 check
mode (See page 4-1 1).
Enter "O"in the memory display and "9" in the copy counter.
Press the Print Start key to turn on the master feed clamper solenoid [A].
Make sure that the distance between the bushing and the edge of the
opening cam [B] is 29~0.5 mm when the master feed clamper solenoid turns
on.
If not, loosen the mounting screws [C] and adjust the solenoid position.
ICAUTION:
Do not turn on the solenoid any longer than 10 seconds.
I
7, After adjustment,
retighten the mounting screws.