3.10 Adjustment of the RADF (MR-3016)

3.10.1
Adjustment of RADF position
It is mainly performed at the installation. It is also required when the RADF is dislocated for some rea-
son such as moving the equipment.
Remove the platen sheet during adjustment.
<Procedure>
(1)
Open the RADF and then attach 2 position-
ing pins to the equipment.
(The positioning pins have been attached at
the rear of the right-hand hinge of the RADF.)
(2)
Close the RADF to check that the positioning
pins fit smoothly into the holes on the RADF.
If they do not, adjust them according to the
following procedure.
(3)
Loosen the stepped screw 1 turn and 2
screws on the adjustment plate a half turn
(status of temporary fixing).
June 2004 © TOSHIBA TEC
Positioning pin
Fig.3-50
Fig.3-51
Half turn
1 turn
Fig.3-52
e-STUDIO200L/202L/230/232/280/282 ADJUSTMENT