3.12 Adjustment of the RADF (MR-3018)
3.12.1
Adjustment of RADF Position
Perform this adjustment when the RADF is not installed in the correct position.
Note:
Note:
Check if the image adjustment for the equipment is performed properly before this adjustment of
the RADF.
[A]
Checking
(1)
Open the RADF and install 2 positioning pins
(the positioning pins are installed to the back
side of the hinge which is on the left side of
the RADF).
(2)
Remove the platen sheet.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Fig. 3-36
Fig. 3-37
3 - 63
e-STUDIO281c/351c/451c
ADJUSTMENT
3