11.6 Connecting a Safety Function Device

11.6

Connecting a Safety Function Device

Use the following procedure to connect a safety function device.
1.
Remove the Safety Jumper Connector from the connector for the safety function device
(CN8).
2.
Connect the safety function device to the connector for the safety function device
(CN8).
Note: If you do not connect a safety function device, leave the Safety Jumper Connector connected to the connec-
tor for the safety function device (CN8). If the SERVOPACK is used without the Safety Jumper Connector
connected to CN8, no current will be supplied to the Servomotor and no motor torque will be output. In this
case, Hbb will be displayed on the Digital Operator.
11-14
Enlarged
View
Hold the Safety Jumper
Connector between your
Safety Jumper
fingers and remove it.
Connector