YASKAWA SGD7S Product Manual page 481

Servopack with mechatrolink-iii
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

Parameter
Name
No.
Application Function
2
Selections A
Motor Stopping Method for Group 2 Alarms

n.
X
Pn00A
Stopping Method for Forced Stops

n.
X

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Application Function
2
Selections B
Operator Parameter Display Selection

n.
X
Motor Stopping Method for Group 2 Alarms

n.
X
Pn00B
Power Input Selection for Three-phase SERVOPACK

n.
X

n.X
Reserved parameter (Do not change.)
Setting
Setting
Range
Unit
0000 to
0044
Apply the dynamic brake or coast the motor to a stop (use the
0
stopping method set in Pn001 = n.X).
Decelerate the motor to a stop using the torque set in Pn406 as
1
the maximum torque. Use the setting of Pn001 = n.X for the
status after stopping.
Decelerate the motor to a stop using the torque set in Pn406 as
2
the maximum torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in
3
Pn30A. Use the setting of Pn001 = n.X for the status after
stopping.
Decelerate the motor to a stop using the deceleration time set in
4
Pn30A and then let the motor coast.
Apply the dynamic brake or coast the motor to a stop (use the
0
stopping method set in Pn001 = n.X).
Decelerate the motor to a stop using the torque set in Pn406 as
1
the maximum torque. Use the setting of Pn001 = n.X for the
status after stopping.
Decelerate the motor to a stop using the torque set in Pn406 as
2
the maximum torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in
3
Pn30A. Use the setting of Pn001 = n.X for the status after
stopping.
Decelerate the motor to a stop using the deceleration time set in
4
Pn30A and then let the motor coast.
0000 to
1121
0
Display only setup parameters.
1
Display all parameters.
0
Stop the motor by setting the speed reference to 0.
Apply the dynamic brake or coast the motor to a stop (use the
1
stopping method set in Pn001 = n.X).
2
Set the stopping method with Pn00A = n.X.
0
Use a three-phase power supply input.
Use a three-phase power supply input as a single-phase power
1
supply input.
13.1 List of Servo Parameters
13.1.2 List of Servo Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
After
0001
All
restart
After
0000
All
restart
Continued on next page.
Classi-
Refer-
fication
ence
Setup
Reference
page 5-37
Reference
page 6-58
Setup
Reference
page 5-3
Reference
page 5-37
Reference
page 5-12
13
13-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents