5.1 Manipulating Parameters (Pn)

5.1.4 Write Prohibition Setting for Parameters

6.
Select Edited Parameters in the Write to Servo Group.
The edited parameters are written to the SERVOPACK and the backgrounds of the cells change to
white.
7.
Click the OK Button.
8.
To enable changes to the settings, turn the power supply to the SERVOPACK OFF and
ON again.
This concludes the procedure to set the parameters.
Setting Parameters with a Digital Operator
Refer to the following manual for information on setting the parameters with a Digital Operator.
Σ-7-Series Digital Operator Operating Manual (Manual No.: SIEP S800001 33)
5.1.4

Write Prohibition Setting for Parameters

You can prohibit writing parameters from the Digital Operator.
Even if you do, you will still be able to change parameter settings from the SigmaWin+.
Preparations
No preparations are required.