YASKAWA SGD7S Product Manual page 360

Servopack with mechatrolink-iii
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

8.13 Manual Tuning
8.13.2 Compatible Adjustment Functions
 Using the Acceleration as the Mode Switching Condition
• Rotary Servomotors
When the speed reference equals or exceeds the acceleration rate set for the mode switching
level for acceleration (Pn10E), the speed loop is changed to P control.
Speed
+Pn10E
Speed 0
- Pn10E
• Linear Servomotors
When the speed reference equals or exceeds the acceleration rate set for the mode switching
level for acceleration (Pn182), the speed loop is changed to P control.
Acceleration 0
 Using the Position Deviation as the Mode Switching Condition
When the position deviation equals or exceeds the value set for the mode switching level for
position deviation (Pn10F), the speed loop is changed to P control.
This setting is enabled only for position control.
Position deviation
Position Integral
The position integral is the integral function of the position loop. It is used for the electronic
cams and electronic shafts when using the SERVOPACK with a Yaskawa MP3000-Series
Machine Controller.
Pn11F
8-94
Speed reference
Motor speed
Motor acceleration
PI
P
PI control
P
Speed reference
Speed
Motor acceleration
+Pn182
- Pn182
PI
P
PI control
Speed reference
Speed
Pn10F
PI
P control
Position Integral Time Constant
Setting Range
0 to 50,000
Time
PI control
Motor speed
Time
P
PI control
Motor speed
Time
PI control
Setting Unit
Default Setting
0.1 ms
0
Position
When Enabled
Classification
Immediately
Tuning

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents