Restrictions - YASKAWA SGD7S Product Manual

Servopack with mechatrolink-iii
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

Movement
speed
References
Responses
SERVOPACK
Note: Execute autotuning without a host reference after jogging to
a position that ensures a suitable range of motion.
 Autotuning without a host reference requires operating the motor and therefore presents
hazards. Observe the following precaution.
• Confirm safety around moving parts.
This function involves automatic operation with vibration. Make sure that you can perform an
emergency stop (to turn OFF the power supply) at any time. There will be movement in both
directions within the set range of movement. Check the range of movement and the directions
and implement protective controls for safety, such as the overtravel functions.
8.6.2

Restrictions

The following restrictions apply to autotuning without a host reference.
If you cannot use autotuning without a host reference because of these restrictions, use auto-
tuning with a host reference or custom tuning. Refer to the following sections for details.
8.7 Autotuning with a Host Reference on page 8-35
8.8 Custom Tuning on page 8-42
Systems for Which Execution Cannot Be Performed
• When the machine system can move only in one direction
• When the range of motion is 0.5 rotations or less
Systems for Which Adjustments Cannot Be Made
Accurately
• When a suitable range of motion is not possible
• When the moment of inertia changes within the set operating range
• When the machine has high friction
• When the rigidity of the machine is low and vibration occurs when positioning is performed
• When the position integration function is used
• When proportional control is used
Note: If you specify calculating the moment of inertia, an error will occur if V_PPI in the servo command output
signals (SVCMD_IO) changes to specify the proportional action during moment of inertia estimation.
• When mode switching is used
Note:If you specify moment of inertia estimation, mode switching will be disabled and PI control will be used
while the moment of inertia is being calculated. Mode switching will be enabled after moment of inertia esti-
mation has been completed.
• When speed feedforward or torque feedforward is input
• When the positioning completed width (Pn522) is too narrow
Travel Distance
Servomotor
WARNING
8.6 Autotuning without Host Reference
Rated motor speed
 2/3
Rated motor speed
 2/3
Motor rated torque:
Approx. 100%
Motor rated torque:
Approx. 100%
Example of Automatic Operation Pattern

8.6.2 Restrictions

Time t
Time t
8
8-25

Hide quick links: