6.1 I/O Signal Allocations

6.1.3 ALM (Servo Alarm) Signal

6.1.3

ALM (Servo Alarm) Signal

This signal is output when the SERVOPACK detects an error.
Important
Type
Output
Alarm Reset Methods
Refer to the following section for information on the alarm reset methods.
12.2.3 Resetting Alarms on page 12-42
6.1.4

/WARN (Warning) Signal

Both alarms and warnings are generated by the SERVOPACK. Alarms indicate errors in the
SERVOPACK for which operation must be stopped immediately. Warnings indicate situations
that may results in alarms but for which stopping operation is not yet necessary.
The /WARN (Warning) signal indicates that a condition exists that may result in an alarm.
Type
Output
Note: You must allocate the /WARN signal to use it. Use Pn50F = n.X (/WARN (Warning Output) Signal Allo-
cation) to allocate the signal to a connector pin. Refer to the following section for details.
6.1.5

/TGON (Rotation Detection) Signal

The /TGON signal indicates that the Servomotor is operating.
This signal is output when the shaft of the Servomotor rotates at the setting of Pn502 (Rotation
Detection Level) or faster or the setting of Pn581 (Zero Speed Level) or faster.
Type
Output
Note: You must allocate the /TGON signal to use it. Use Pn50E = n.X (/TGON (Rotation Detection Output)
Signal Allocation) to allocate the signal to a connector pin. Refer to the following section for details.
6-8
Configure an external circuit so that this alarm output turns OFF the main circuit power supply to
the SERVOPACK whenever an error occurs.
Signal
Connector Pin No.
ALM
CN1-3 and CN1-4
Signal
Connector Pin No.
/WARN
Must be allocated.
6.1.2 Output Signal Allocations on page 6-6
Signal
Connector Pin No.
/TGON
Must be allocated.
6.1.2 Output Signal Allocations on page 6-6
Signal Status
ON (closed)
Normal SERVOPACK status
OFF (open)
SERVOPACK alarm
Signal Status
ON (closed)
Warning
OFF (open)
Normal status
Signal Status
Servomotor
Rotary Servomotors
ON (closed)
Linear Servomotors
Rotary Servomotors
OFF (open)
Linear Servomotors
Meaning
Meaning
Meaning
The Servomotor is
operating at the setting
of Pn502 or faster.
The Servomotor is
operating at the setting
of Pn581 or faster.
The Servomotor is
operating at a speed
that is slower than the
setting of Pn502.
The Servomotor is
operating at a speed
that is slower than the
setting of Pn581.