YASKAWA SGD7S Product Manual page 432

Servopack with mechatrolink-iii
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

12.2 Alarm Displays
12.2.2 Troubleshooting Alarms
Alarm Number:
Alarm Name
A.860:
Encoder Over-
heated
(Detected when a
Rotary Servomo-
tor, Absolute Lin-
ear Encoder, or
Direct Drive Ser-
vomotor is con-
nected. However,
this alarm is not
detected for
SGMCS
Servomotors with
Incremental
Encoders.)
(Detected at the
encoder.)
A.861:
Motor Over-
heated
A.890:
Encoder Scale
Error
A.891:
Encoder Module
Error
A.8A0:
External Encoder
Error
12-26
Possible Cause
The surrounding air
Measure the surround-
temperature around
ing air temperature
the Servomotor is too
around the Servomotor.
high.
The Servomotor load
Use the accumulated
is greater than the
load ratio to check the
rated load.
load.
A failure occurred in
the encoder.
A failure occurred in
the SERVOPACK.
The surrounding tem-
Measure the surround-
perature around the
ing temperature around
Servomotor is too
the Servomotor.
high.
Check the load with the
The motor load is
accumulated load ratio
greater than the rated
on the Motion Monitor
load.
Tab Page on the Sig-
maWin+.
A failure occurred in
the Serial Converter
Unit.
A failure occurred in
the SERVOPACK.
A failure occurred in
the linear encoder.
A failure occurred in
the linear encoder.
Setting the origin of
Before you set the ori-
the absolute linear
gin, use the fully-closed
encoder failed
feedback pulse counter
because the motor
to confirm that the
moved.
motor is not moving.
A failure occurred in
the external encoder.
Confirmation
Reduce the surrounding
air temperature of the
Servomotor to 40°C or
less.
Operate the Servo Drive
so that the motor load
remains within the speci-
fied range.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the Servomotor or
absolute linear encoder
may be faulty. Replace the
Servomotor or absolute
linear encoder.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Reduce the surrounding
air temperature of the
Servomotor to 40° or less.
Operate the Servo Drive
so that the motor load
remains within the speci-
fied range.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the Serial Con-
verter Unit may be faulty.
Replace the Serial Con-
verter Unit.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
The linear encoder may
be faulty. Replace the lin-
ear encoder.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the linear encoder
may be faulty. Replace the
linear encoder.
The motor must be
stopped while setting the
origin position.
Replace the external
encoder.
Continued from previous page.
Correction
Reference
page 9-3
page 9-3
page 5-49
Continued on next page.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents