10.3 Parameter Settings for Fully-Closed Loop Control

10.3.2 Setting the Motor Direction and the Machine Movement Direction

10.3.2 Setting the Motor Direction and the Machine Movement
Direction
You must set the motor direction and the machine movement direction. To perform fully-closed
loop control, you must set the motor rotation direction with both Pn000 = n.X (Direction
Selection) and Pn002 = n.X (External Encoder Usage).
Pn000
=n.X
(Direction
Selection)
• Phase B leads in the divided pulses for a forward reference regardless of the setting of Pn000
= n.X.
• Forward direction: The direction in which the pulses are counted up.
• Reverse direction: The direction in which the pulses are counted down.
Related Parameters
 Pn000 = n.
Refer to the following section for details.
5.5 Motor Direction Setting on page 5-15
 Pn002 = n.X
When you perform fully-closed loop control, set Pn002 to n.1 or n.3.
Pn002
Information
10-6
Parameter
Reference
direction

n.
0
Motor direction
External
encoder
Reference
direction

n.
1
Motor direction
External
encoder

X

Parameter
Name
n.0
(default set-
ting)

n.1
External
Encoder Usage

n.2

n.3

n.4
Determine the setting of Pn002 = n.X as described below.
• Set Pn000 to n.0 (Use the direction in which the linear encoder counts up as the for-
ward direction) and set Pn002 to n.1 (The external encoder moves in the forward
direction for CCW motor rotation).
• Manually rotate the motor shaft counterclockwise.
• If the fully-closed feedback pulse counter counts up, do not change the setting of Pn002
(Pn002 = n.1).
• If the fully-closed feedback pulse counter counts down, set Pn002 to n.3.
Pn002 = n.X (External Encoder Usage)

n.1
Forward
Reverse
reference
reference
CCW
CW
Forward
Reverse
movement
movement
Forward
Reverse
reference
reference
CW
CCW
Reverse
Forward
movement
movement
Meaning
Do not use an external encoder.
External encoder moves in forward
direction for CCW motor rotation.
Reserved parameter (Do not change.)
External encoder moves in reverse direc-
tion for CCW motor rotation.
Reserved parameter (Do not change.)

n.3
Forward
Reverse
reference
reference
CCW
CW
Reverse
Forward
movement
movement
Forward
Reverse
reference
reference
CW
CCW
Forward
Reverse
movement
movement
When