YASKAWA SGD7S Product Manual page 495

Servopack with mechatrolink-iii
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

Parameter
Name
No.
Input Signal Selections
2
2
N-OT (Reverse Drive Prohibit) Signal Allocation

n.
X

n.
X
Reserved parameter (Do not change.)
Pn50B
/P-CL (Forward External Torque Limit Input) Signal Allocation

n.
X
/N-CL (Reverse External Torque Limit Input) Signal Allocation

n.X
Setting
Setting
Range
Unit
0000 to
FFFF
0
Enable reverse drive when CN1-13 input signal is ON (closed).
1
Enable reverse drive when CN1-7 input signal is ON (closed).
2
Enable reverse drive when CN1-8 input signal is ON (closed).
3
Enable reverse drive when CN1-9 input signal is ON (closed).
4
Enable reverse drive when CN1-10 input signal is ON (closed).
5
Enable reverse drive when CN1-11 input signal is ON (closed).
6
Enable reverse drive when CN1-12 input signal is ON (closed).
7
Set the signal to always prohibit reverse drive.
8
Set the signal to always enable reverse drive.
9
Enable reverse drive when CN1-13 input signal is OFF (open).
A
Enable reverse drive when CN1-7 input signal is OFF (open).
B
Enable reverse drive when CN1-8 input signal is OFF (open).
C
Enable reverse drive when CN1-9 input signal is OFF (open).
D
Enable reverse drive when CN1-10 input signal is OFF (open).
E
Enable reverse drive when CN1-11 input signal is OFF (open).
F
Enable reverse drive when CN1-12 input signal is OFF (open).
0
Active when CN1-13 input signal is ON (closed).
1
Active when CN1-7 input signal is ON (closed).
2
Active when CN1-8 input signal is ON (closed).
3
Active when CN1-9 input signal is ON (closed).
4
Active when CN1-10 input signal is ON (closed).
5
Active when CN1-11 input signal is ON (closed).
6
Active when CN1-12 input signal is ON (closed).
7
The signal is always active.
8
The signal is always inactive.
9
Active when CN1-13 input signal is OFF (open).
A
Active when CN1-7 input signal is OFF (open).
B
Active when CN1-8 input signal is OFF (open).
C
Active when CN1-9 input signal is OFF (open).
D
Active when CN1-10 input signal is OFF (open).
E
Active when CN1-11 input signal is OFF (open).
F
Active when CN1-12 input signal is OFF (open).
The allocations are the same as the /P-CL (Forward External
0 to F
Torque Limit Input) signal allocations.
13.1 List of Servo Parameters
13.1.2 List of Servo Parameters
Continued from previous page.
Default
Applicable
Setting
Motors
Enabled
8882
All
When
Classi-
Refer-
fication
ence
After
Setup
restart
Reference
page 5-27
Reference
page 6-28
Reference
page 6-28
Continued on next page.
13-23
13

Hide quick links:

Advertisement

Table of Contents
loading