8.11 Speed Ripple Compensation

8.11.1 Outline

8.11

Speed Ripple Compensation

This section describes speed ripple compensation.

8.11.1 Outline

Speed ripple compensation reduces the amount of ripple in the motor speed due to torque rip-
ple or cogging torque. You can enable speed ripple compensation to achieve smoother opera-
tion. To enable it, you must set up ripple compensation on the SigmaWin+.
Important

8.11.2 Setting Up Speed Ripple Compensation

Restrictions
The following restrictions apply to the setup for speed ripple compensation.
 Systems for Which Execution Cannot Be Performed
There are no restrictions.
 Systems for Which Adjustments Cannot Be Made Accurately
Systems for which there is not a suitable range of motion
 Preparations
Always check the following before you set up speed ripple compensation.
• The main circuit power supply must be ON.
• The servo must be OFF.
• There must be no alarms or warnings.
• There must be no hard wire base block (HWBB).
• The parameters must not be write prohibited.
8-60
 Speed ripple compensation requires operating the motor and therefore presents hazards.
Observe the following precaution.
Confirm safety around moving parts.
This function involves automatic operation. Make sure that you can perform an emergency stop
(to turn OFF the power supply) at any time.
Execute speed ripple compensation only after adjusting the gains.
• Reset speed ripple compensation after you replace the Servomotor or SERVOPACK.
• Execute speed ripple compensation after jogging to a position that ensures a suitable range of
motion.