Initializing Parameter Settings - YASKAWA SGD7S Product Manual

Servopack with mechatrolink-iii
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

Button in
Menu
Dialog Box
Jogging
Test Opera-
tion
Program Jogging
Display Alarm
Alarm
Reset Motor Type Alarm
*
An Initialize Button will be displayed in the Parameter Editing Dialog Box.
5.1.5

Initializing Parameter Settings

You can return the parameters to their default settings.
This function will not initialize the settings of the parameters that are adjusted for the Fn00C,
Fn00D, Fn00E, and Fn00F utility functions.
To enable the new settings, turn the power supply to the SERVOPACK OFF and ON again after
you complete the operation.
Important
Preparations
Always check the following before you initialize the parameter settings.
• The parameters must not be write prohibited.
• The servo must be OFF.
Applicable Tools
The following table lists the tools that you can use to initialize the parameter settings and the
applicable tool functions.
Tool
Digital Operator
SigmaWin+
SigmaWin+
SigmaWin+ Function
Name
Function
Fn005
Parameters - Edit Parameters
5.1 Manipulating Parameters (Pn)
Digital Operator
Fn No.
Utility Function Name
Fn002
Jog
Fn004
Jog Program
Fn000
Display Alarm History
Fn006
Clear Alarm History
Fn021
Reset Motor Type Alarm

5.1.5 Initializing Parameter Settings

Continued from previous page.
When Writ-
ing Is Pro-
Reference
hibited
Cannot be
page 7-7
executed.
Cannot be
page 7-14
executed.
Can be
page 12-43
executed.
Cannot be
page 12-44
executed.
Cannot be
page 5-14
executed.
Reference
Σ-7-Series Digital Operator Operating
Manual (Manual No.: SIEP S800001
33)
Operating Procedure on page 5-10
5
5-9

Hide quick links: