Using A Tool Function To Perform Polarity Detection - YASKAWA SGD7S Product Manual

Servopack with mechatrolink-iii
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

5.10 Polarity Detection

5.10.3 Using a Tool Function to Perform Polarity Detection

5.10.3 Using a Tool Function to Perform Polarity Detection
Applicable Tools
The following table lists the tools that you can use to perform polarity detection and the appli-
cable tool functions.
Digital Operator
SigmaWin+
Operating Procedure
Use the following procedure to perform polarity detection.
1.
Click the
2.
Select Polarity Detection in the Menu Dialog Box.
The Polarity Detection Dialog Box will be displayed.
3.
Click the Continue Button.
Click the Cancel Button to cancel polarity detection. The Main Window will return.
4.
Click the Start Button.
Polarity detection will be executed.
This concludes the polarity detection procedure.
5-26
Tool
Fn080
Setup - Polarity Detection
Servo Drive Button in the workspace of the Main Window of the SigmaWin+.
Function
Reference
Σ-7-Series Digital Operator Operating
Manual (Manual No.: SIEP S800001 33)
Operating Procedure on page 5-26

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents