YASKAWA SGD7S Product Manual page 460

Servopack with mechatrolink-iii
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

12.3 Warning Displays
12.3.2 Troubleshooting Warnings
Warning Number:
Warning Name
A.942:
Speed Ripple Com-
pensation Informa-
tion Disagreement
A.94A:
Data Setting Warn-
ing 1 (Parameter
Number Error)
A.94b:
Data Setting Warn-
ing 2 (Out of Range)
A.94C:
Data Setting Warn-
ing 3 (Calculation
Error)
A.94d:
Data Setting Warn-
ing 4 (Parameter
Size)
A.94E:
Data Setting Warn-
ing 5 (Latch Mode
Error)
A.95A:
Command Warning
1 (Unsatisfied Com-
mand Conditions)
A.95b:
Command Warning
2 (Unsupported
Command)
A.95d:
Command Warning
4 (Command Inter-
ference)
A.95E:
Command Warning
5 (Subcommand
Not Possible)
12-54
Possible Cause
Confirmation
The speed ripple
compensation
information stored
in the encoder
does not agree
with the speed
ripple compensa-
tion information
stored in the SER-
VOPACK.
An invalid param-
Check the command
eter number was
that caused the warn-
used.
ing.
The set com-
mand data was
Check the command
clamped to the
that caused the warn-
minimum or maxi-
ing.
mum value of the
setting range.
The calculation
Check the command
result of the set-
that caused the warn-
ting is not correct.
ing.
The parameter
Check the command
size set in the
that caused the warn-
command is not
ing.
correct.
Check the command
A latch mode error
that caused the warn-
was detected.
ing.
The command
Check the command
conditions are not
that caused the warn-
satisfied.
ing.
Check the command
An unsupported
command was
that caused the warn-
received.
ing.
The command
sending condi-
Check the command
tions for latch-
that caused the warn-
related com-
ing.
mands was not
satisfied.
The command
sending condi-
Check the command
tions for subcom-
that caused the warn-
mands was not
ing.
satisfied.
Continued from previous page.
Correction
Reset the speed ripple
compensation value on the
SigmaWin+.
Set Pn423 to n.1 (Do
not detect A.942 alarms).
However, changing the set-
ting may increase the speed
ripple.
Set Pn423 to n.0
(Disable speed ripple com-
pensation). However,
changing the setting may
increase the speed ripple.
Use the correct parameter
number.
Set the parameter within
the setting range.
Set the parameter within
the setting range.
Set the correct parameter
size.
Change the setting of
Pn850 or the LT_MOD data
for the LTMOD_ON com-
mand sent by the host con-
troller to an appropriate
value.
(The applies when using the
MECHATROLINK-II-com-
patible profile.)
Send the command after
the command conditions
are satisfied.
Do not send unsupported
commands.
Send the command after
the command conditions
are satisfied.
Send the command after
the conditions are satisfied.
Continued on next page.
Reference
page 8-60
page 8-60
page 8-60
page 12-
57
page 12-
57
page 12-
57
page 12-
57
page 12-
57
page 12-
57
page 12-
57
page 12-
57
page 12-
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents