12.2 Alarm Displays
12.2.1 List of Alarms
Alarm
Number
A.F50
*
FL-1
*
FL-2
*
FL-3
*
FL-4
*
FL-5
*
FL-6
CPF00
CPF01
*
These alarms are not stored in the alarm history. They are only displayed on the panel display.
Note: The A.Eb0, A.Eb2 to A.Eb9, and A.EC0 to A.EC2 alarms can occur when a Safety Module is connected.
Refer to the following manual for details.
12-10
Alarm Name
Servomotor Main Circuit
Cable Disconnection
System Alarm
Digital Operator Commu-
nications Error 1
Digital Operator Commu-
nications Error 2
Σ
Σ
AC Servo Drive
-V-Series/
-V-Series for Large-Capacity Models/
No.: SIEP C720829 06)
Alarm Meaning
The Servomotor did not operate or power was
not supplied to the Servomotor even though the
SV_ON (Servo ON) command was input when the
Servomotor was ready to receive it.
An internal program error occurred in the SER-
VOPACK.
Communications were not possible between the
Digital Operator (model: JUSP-OP05A-1-E) and
the SERVOPACK (e.g., a CPU error occurred).
Continued from previous page.
Servo-
motor
Stop-
ping
Method
Gr.1
Σ
-7-Series User's Manual Safety Module (Manual
Alarm
Reset
Possi-
ble?
Yes
No
No

Hide quick links: