YASKAWA SGD7S Product Manual page 202

Servopack with mechatrolink-iii
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

6.5 Encoder Divided Pulse Output
6.5.1 Encoder Divided Pulse Output Signals
 When First Passing the Origin Signal in the Forward Direction and Returning after
Turning ON the Power Supply
The encoder's phase-C pulse (CN1-21 and CN1-22) is output when the origin detection posi-
tion is passed for the first time in the forward direction after the power supply is turned ON.
After that, the phase-C pulse is output whenever the origin detection position is passed in the
forward or reverse direction.
Encoder count-up
direction
Origin detection
position
Phase-C pulse
output
 When First Passing the Origin Signal in the Reverse Direction and Returning after
Turning ON the Power Supply
The encoder's phase-C pulse (CN1-19 and CN1-20) is not output when the origin detection
position is passed for the first time in the reverse direction after the power supply is turned ON.
However, after the origin detection position is passed in the forward direction and the encoder's
phase-C pulse is output, it will then also be output when the origin detection point is passed in
the reverse direction.
Encoder count-up
direction
Origin detection
position
Phase-C pulse
output
 When Using a Linear Encoder with Multiple Origins and First Passing the Origin Posi-
tion in the Forward Direction and Returning after Turning ON the Power Supply
The encoder's phase-C pulse is output when the origin detection position is passed for the first
time in the forward direction after the power supply is turned ON. After that, the phase-C pulse
is output whenever the origin detection position is passed in the forward or reverse direction.
Encoder count-up
direction
Origin 1 detection
position
Origin 2 detection
position
Phase-C pulse
output
6-22
Power ON
position
Power ON
position
Power ON
Origin 1
Origin 1
The SERVOPACK records the position where
the phase-C pulse was output for movement
in the forward direction, and the phase-C
pulse is also output for reverse movement.
Time
The phase-C pulse is not
output when the detection
position is passed in the
reverse direction.
Time
The SERVOPACK records the position where
the phase-C pulse was output for movement
in the forward direction, and the phase-C
pulse is then output for reverse movement.
The SERVOPACK records the position where
the phase-C pulse was output for movement
in the forward direction, and the phase-C
pulse is also output for reverse movement.
Time
Even after origin 1 has been passed in
the forward direction, the phase-C pulse
is not output here because origin 2 is
passed in the reverse direction.
Origin 2
Origin 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents