Connecting A Safety Function Device - YASKAWA SGD7S series Product Manual

Sigma-7-series ac servo drive. sigma-7s servopack with analog voltage/pulse train references
Hide thumbs Also See for SGD7S series:
Table of Contents

Advertisement

11.6 Connecting a Safety Function Device

11.6

Connecting a Safety Function Device

Use the following procedure to connect a safety function device.
1.
Remove the Safety Jumper Connector from the connector for the safety function device
(CN8).
2.
Connect the safety function device to the connector for the safety function device
(CN8).
Note: If you do not connect a safety function device, leave the Safety Jumper Connector connected to the connec-
tor for the safety function device (CN8). If the SERVOPACK is used without the Safety Jumper Connector
connected to CN8, no current will be supplied to the Servomotor and no motor torque will be output. In this
case, Hbb will be displayed on the Digital Operator.
11-12
Enlarged
View
Hold the afety Jumper
Connector between your
afety Jumper
finger and remove it.
Connector