Using The Sigmawin - YASKAWA SGD7S Product Manual

Servopack with mechatrolink-iii
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

9.3.2

Using the SigmaWin+

This section describes how to trace data and I/O with the SigmaWin+.
Refer to the following manual for detailed operating procedures for the SigmaWin+.
AC Servo Drive Engineering Tool SigmaWin+ Operation Manual (Manual No.: SIET S800001 34)
Operating Procedure
1.
Click the
maWin+.
2.
Select Trace in the Menu Dialog Box.
The Trace Dialog Box will be displayed.
Trace Objects
You can trace the following items.
• Data Tracing
• Torque Reference
• Feedback Speed
• Reference Speed
• Position Reference Speed
• Position Error (Deviation)
• Position Amplifier Error (Deviation)
9.3 Monitoring Machine Operation Status and Signal Waveforms
Servo Drive Button in the workspace of the Main Window of the Sig-
Trace Objects
• Motor - Load Position Deviation
• Speed Feedforward
• Torque Feedforward
• Effective (Active) Gain
• Main Circuit DC Voltage
• External Encoder Speed
• Control Mode

9.3.2 Using the SigmaWin+

Click this button to display the Trace Setting
Dialog Box shown below, and set the data to
trace and the trace conditions.
9
9-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents