YASKAWA SGD7S Product Manual page 500

Servopack with mechatrolink-iii
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

13.1 List of Servo Parameters
13.1.2 List of Servo Parameters
Parameter
No.
Pn516
*3
Pn518
Pn51B
Pn51E
Pn520
Pn522
Pn524
Pn526
Pn528
Pn529
Pn52A
Pn52B
13-28
Name
Input Signal Selections
2
7
FSTP (Forced Stop Input) Signal Allocation
0
Enable drive when CN1-13 input signal is ON (closed).
1
Enable drive when CN1-7 input signal is ON (closed).
2
Enable drive when CN1-8 input signal is ON (closed).
3
Enable drive when CN1-9 input signal is ON (closed).
4
Enable drive when CN1-10 input signal is ON (closed).
5
Enable drive when CN1-11 input signal is ON (closed).
6
Enable drive when CN1-12 input signal is ON (closed).
Set the signal to always prohibit drive (always force the motor to
7

n.
X
stop).
Set the signal to always enable drive (always disable forcing the
8
motor to stop).
9
Enable drive when CN1-13 input signal is OFF (open).
A
Enable drive when CN1-7 input signal is OFF (open).
B
Enable drive when CN1-8 input signal is OFF (open).
C
Enable drive when CN1-9 input signal is OFF (open).
D
Enable drive when CN1-10 input signal is OFF (open).
E
Enable drive when CN1-11 input signal is OFF (open).
F
Enable drive when CN1-12 input signal is OFF (open).

n.
X
Reserved parameter (Do not change.)

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Safety Module-Related
Parameters
Motor-Load Position
4
Deviation Overflow
Detection Level
Position Deviation Over-
2
flow Warning Level
Position Deviation Over-
4
flow Alarm Level
Positioning Completed
4
Width
4
Near Signal Width
Position Deviation Over-
4
flow Alarm Level at
Servo ON
Position Deviation Over-
2
flow Warning Level at
Servo ON
Speed Limit Level at
2
Servo ON
Multiplier per Fully-
2
closed Rotation
2
Overload Warning Level
Setting
Setting
Default
Range
Unit
Setting
0000 to
8888
FFFF
1 refer-
0 to
ence
1000
1,073,741,824
unit
10 to 100
1%
100
1 refer-
1 to
524288
ence
1,073,741,823
0
unit
1 refer-
0 to
ence
7
1,073,741,824
unit
1 refer-
1 to
107374
ence
1,073,741,824
1824
unit
1 refer-
1 to
524288
ence
1,073,741,823
0
unit
10 to 100
1%
100
-1
0 to 10,000
10000
1 min
0 to 100
1%
20
1 to 100
1%
20
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Reference
page 6-58
All
Immedi-
Rotary
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
All
Setup
ately
Immedi-
Rotary
Setup
ately
Immedi-
Rotary
Tuning
ately
Immedi-
All
Setup
ately
Continued on next page.
Refer-
ence
page
10-9
page
12-48
page
8-8,
page
12-5
page
6-11
page
6-12
page
8-8
page
8-8
page
8-8
page
10-9
page
5-39