Parameter
Name
No.
SVCMD_IO Output Sig-
2
nal Monitor Allocations
1
Output Signal Monitor Allocation for CN1-1 and CN1-2 (SVCMD_IO)

n.
X
Pn868
*7
M3
CN1-1/CN1-2 Output Signal Monitor Enable/Disable Selection

n.
X
Output Signal Monitor Allocation for CN1-23 and CN1-24 (SVCMD_IO)

n.
X
0 to 7 The settings are the same as the CN1-1/CN1-2 allocations.
CN1-23/CN1-24 Output Signal Monitor Enable/Disable Selection

n.X
SVCMD_IO Output Sig-
2
nal Monitor Allocations
2
Output Signal Monitor Allocation for CN1-25 and CN1-26 (SVCMD_IO)

n.
X
0 to 7 The settings are the same as the CN1-1/CN1-2 allocations.
Pn869
CN1-25/CN1-26 Output Signal Monitor Enable/Disable Selection
*7
M3

n.
X

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Station Address Moni-
Pn880
2
tor (for maintenance,
read only)
Set Transmission Byte
Count Monitor [bytes]
Pn881
2
(for maintenance, read
only)
Transmission Cycle Set-
ting Monitor [× 0.25 μs]
Pn882
2
(for maintenance, read
only)
Communications Cycle
Setting Monitor [trans-
Pn883
2
mission cycles] (for
maintenance, read only)
Setting
Setting
Range
Unit
0000 to
1717
0
Allocate bit 24 (IO_STS1) to CN1-1/CN1-2 output signal monitor.
1
Allocate bit 25 (IO_STS2) to CN1-1/CN1-2 output signal monitor.
2
Allocate bit 26 (IO_STS3) to CN1-1/CN1-2 output signal monitor.
3
Allocate bit 27 (IO_STS4) to CN1-1/CN1-2 output signal monitor.
4
Allocate bit 28 (IO_STS5) to CN1-1/CN1-2 output signal monitor.
5
Allocate bit 29 (IO_STS6) to CN1-1/CN1-2 output signal monitor.
6
Allocate bit 30 (IO_STS7) to CN1-1/CN1-2 output signal monitor.
7
Allocate bit 31 (IO_STS8) to CN1-1/CN1-2 output signal monitor.
0
Disable allocation for CN1-1/CN1-2 output signal monitor.
1
Enable allocation for CN1-1/CN1-2 output signal monitor.
0
Disable allocation for CN1-23/CN1-24 output signal monitor.
1
Enable allocation for CN1-23/CN1-24 output signal monitor.
0000 to
1717
0
Disable allocation for CN1-25/CN1-26 output signal monitor.
1
Enable allocation for CN1-25/CN1-26 output signal monitor.
03 to EF
17, 32, 48
0 to FFFF
0 to 32
13.1 List of Servo Parameters
13.1.2 List of Servo Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
Immedi-
0000
All
ately
Immedi-
0000
All
ately
All
All
All
All
Continued on next page.
Classi-
Refer-
fication
ence
*1
Setup
*1
Setup
page
Setup
5-11
page
Setup
5-11
page
Setup
5-11
page
Setup
5-11
13
13-43