Applicable Tools
The following table lists the tools that you can use to change the Write Prohibition Setting and
the applicable tool functions.
Tool
Digital Operator
Fn010
SigmaWin+
Setup - Write Prohibited Setting
Operating Procedure
Use the following procedure to prohibit or permit writing parameter settings.
1.
Click the
Servo Drive Button in the workspace of the Main Window of the SigmaWin+.
2.
Select Write Prohibition Setting in the Menu Dialog Box.
The Write Prohibition Setting Dialog Box will be displayed.
3.
Press the
or
0000: Writing is permitted (default setting).
0001: Writing is prohibited.
4.
Click the Setting Button.
5.
Click the OK Button.
The setting will be written to the SERVOPACK.
6.
To enable the new setting, turn the power supply to the SERVOPACK OFF and ON
again.
This concludes the procedure to prohibit or permit writing parameter settings.
Function
for the rightmost digit and set one of the following.
5.1 Manipulating Parameters (Pn)
5.1.4 Write Prohibition Setting for Parameters
Reference
Σ-7-Series Digital Operator Operating
Manual (Manual No.: SIEP S800001
33)
Operating Procedure on page 5-7
5
5-7