Setting The Number Of External Encoder Scale Pitches; Setting The Pao, Pbo, And Pco (Encoder Divided Pulse Output); Signals; Setting The Number Of External Encoder Scale - YASKAWA SGD7S Product Manual

Servopack with mechatrolink-iii
Hide thumbs Also See for SGD7S:
Table of Contents

Advertisement

10.3.3

Setting the Number of External Encoder Scale Pitches

Set the number of external encoder scale pitches per motor rotation in Pn20A.
Setting Example
Specifications
External encoder scale pitch: 20 μm
Ball screw lead: 30 mm
If the external encoder is connected directly to the motor, the setting will be 1,500 (30 mm/0.02
mm = 1,500).
Note: 1. If there is a fraction, round off the digits below the decimal point.
2. If the number of external encoder scale pitches per motor rotation is not an integer, there will be deviation
in the position loop gain (Kp), feedforward, and position reference speed monitor. This is not relevant for
the position loop and it therefore does not interfere with the position accuracy.
Related Parameters
Number of External Encoder Scale Pitches
Setting Range
Pn20A
4 to 1,048,576
10.3.4
Setting the PAO, PBO, and PCO (Encoder Divided Pulse
Output) Signals
Set the position resolution in Pn281 (Encoder Output Resolution).
Enter the number of phase A and phase B edges for the setting.
Setting Example
Specifications
External encoder scale pitch: 20 μm
Ball screw lead: 30 mm
Speed:1,600 mm/s
If a single pulse (multiplied by 4) is output for 1 μm, the setting would be 20.
If a single pulse (multiplied by 4) is output for 0.5 μm, the setting would be 40.
The encoder divided pulse output would have the following waveform if the setting is 20.
Phase A
Phase B
"↑" indicates the edge positions. In this example, the set value is 20 and therefore the number
of edges is 20.
Note: The upper limit of the encoder signal output frequency (multiplied by 4) is 6.4 Mpps. Do not set a value that
would cause the output to exceed 6.4 Mpps.
If the output exceeds the upper limit, an A.511 alarm (Encoder Output Pulse Overspeed) will be output.
10.3.3 Setting the Number of External Encoder Scale Pitches
Workpiece position
before movement
Setting Unit
1 scale pitch/revo-
lution
Sine wave pitch
10.3 Parameter Settings for Fully-Closed Loop Control
Number of external encoder
pitches per motor rotation
Workpiece position
after movement
Ball screw lead: 30 mm
Default Setting
When Enabled
32,768
After restart
External encoder
(scale pitch: 20 m)
Position
Classification
Setup
10-7