8.14 Diagnostic Tools
8.14.2 Easy FFT
7.
Click the Result Writing Button if you want to set the measurement results in the param-
eters.
This concludes the procedure to set up Easy FFT.
Related Parameters
The following parameters are automatically adjusted or used as reference when you execute
Easy FFT.
Do not change the settings of these parameters during execution of Easy FFT.
Parameter
Pn408
Pn409
Pn40A
Pn40C
Pn40D
Pn456
Yes: The parameter is automatically set.
No: The parameter is not automatically set, but the setting is read during execution.
8-100
Name
Torque-Related Function Selections
First Stage Notch Filter Frequency
First Stage Notch Filter Q Value
Second Stage Notch Filter Frequency
Second Stage Notch Filter Q Value
Sweep Torque Reference Amplitude
Automatic Changes
Yes
Yes
No
Yes
No
No